TECHNICAL DATA
MET 6.3 Technical Data:
Power supply: 110-230V 50/60 Hz
On-board voltage connection: 10-30 V, DC
Dimensions (L x W x H): 406 x 225 x 160 mm
Weight: approx. 5.0 kg
MET 6.3 Gas Analyser Unit Technical Data:
Measurable gases: HC, CO, CO2, O2
Measurement principle: infrared spectrometry HC, CO, CO2
Electrochemical detection: O2
Operating pressure: 750-1100 hPa
Accuracy class: 0 (OIML)
Measurement range / measured value resolution (max.):
CO 0-15 % Vol./0.01
CO2 0-20 % Vol./0.01
HC 0-30000 ppm/1
O2 0-25 % Vol./0.01
Lambda (calculated): 0-9.99/0.01
MET 6.3 Technical Data
Opacity/Particle Concentration Unit:
Measurement principle: absorbance measurement
Heat-up time for measuring cell: 150 s
Measuring range, turbidity: 0-100 %
Measuring range, absorption coefficient: 0-9.99 m-1
Resolution, absorption coefficient: 0.01 m-1
Measuring range, particle concentration: 1-1100 mg/m³
Resolution, particle concentration: 1 mg/m³